Crl 08 51 us alum series bw8200 blast resistant horizontal sliding window 8. Standard test methods for tension testing of metallic materials1 this standard is issued under the. A comparison of existing standards for testing blast. Blast mitigation information click here to view our blast resistant windows and doors brochure. The diverse product line is rated for a variety of commercial and architectural applications. Wfm appendix a specs 10714 pan 3m window film distributor. Astm e 1886 standard test method for performance of exterior windows, curtain walls, doors, and storm shutters impacted by missiles and exposed to cyclic pressure differentials, and, astm e 1996 standard specification fo. Technics focus wind does not break window glass texas tech. This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.
Refer to section 08 80 00 for glass design, analysis, and selection requirements in accord with dod ufc 401001, astm f. Viracon recommended architectural glass specification this specification is written according to the construction specifications institute csi 3part format. Ufc atfp windows dod antiterrorismforce protection windows for military and civilian structures of all types series 4100 single hung and 4150 fixed windows meet level 2 atfp performance in astm 164204 shocktube testing york, pa shock tube testing lab photos courtesy of architectural testing, inc. E 0 practice for determining load resistance of glass in buildings3 e 1886 test method for performance of exterior windows, curtain walls, doors, and storm shutters impacted by. This software will make glass strength calculations using any of three versions of astm e 0 standard practice for determining load resistance of glass in buildings. Chemical resistance astm d 8 pass poissons ratio astm e 2 0. Astm f 2248 is a practice for design and not a test method. Astm e 1996 standard specification for performance of exterior windows, curtain walls, doors and impact protective systems impacted by.
Ufc dod 40 tas 201, 202, 203 ibc 2006 miamidade county product approval performance. The following blast standards pertain to windows, doors, walls, vehicle barriers and other miscellaneous items. Refer to section 08 80 00 for glass design, analysis, and selection requirements in accord with dod ufc 401001, astm f 2248 and astm e 0. Industry standards for blast resistance include astm e 0, astm f 2248, astm f 1642, aama 51006, iso 16933, and iso 16934. Model br 250 4 esw aluminum level iv bullet resistant protection. Astm a792, standard specification for steel sheet, 55% aluminumzinc alloy. Government standards include gsats012003, ufc 401001, and ufc 401002.
Gsats012003, standard test method for glazing and window systems subject to dynamic overpressure loadings 3. Astm c 165111 standard test method for measurement of roll wave optical distortion in heattreated flat glass astm e 546 standard test method for frostdew point of sealed insulating glass units astm e 576 standard test method for frostdew point of sealed insulating glass units in the vertical position astm e 0 16 standard practice for. Performance guide specifications for metal roofing systems. Access astm standards from any browser on your computer, tablet or smart phone. This document provides a broad overview, but may not include all related standards. Section 08 87 window film display hidden notes to specifier. The first test method to be developed in the area of bomb blast was astm f 1642, standard test method for glazing and glazing systems subject to airblast loadings, published in 1996. Viracon recommended architectural glass specification. Ambico blast resistant windows combine outstanding performance characteristics with the appearance of standard metal window products. Window replacement low to moderate blast window, thicker glass or insulated 2 tempered glass stronger than annealed, plus less hazardous shards 3 laminated moderate to high blast atfp windows dod antiterrorismforce protection windows for military and civilian structures of all types series 4100 single hung and 4150 fixed windows meet level 2 atfp performance in astm 164204 shocktube testing york, pa shock tube testing lab photos courtesy of architectural testing, inc. Blast cover horizontal format lo res wausau window. The specification can be customized for your project by including details for the products you are specifying in article 2. Ufc atfp windows dod antiterrorismforce protection windows for military and civilian structures of all types series 4100 single hung and 4150 fixed windows meet level 2 atfp performance in astm 164204 shocktube testing york, pa shock tube testing lab photos courtesy of. Introduction to designing fenestration for blast mitigation.
Standards for impact protection custom shutter company. We use the window glass design 2004 software by standards design group. Gsaisc performance conditions for window system response. Our entire range of blast resistant window products is engineered to meet the unique requirements of building projects in a variety of demanding environments. Performance of various glass types in a dryglazed curtain wall system subject to identical dynamic rocking motions. Window design for blast hazard mitigation gale associates. Guideline for specifying steel doors and frames for blast resistance pressure impulse time p max t d blast wave idealized. Blast resistant information protecting building occupants from the effects of bomb blasts. It sets forth a method to specify an equivalent 3second design loading suitable to use with astm e 0 standard practice for determining the load resistance of glass in buildings to select the thickness and type of blast. Astm and haz mat ufc 401001, tm5 0 and pip stc 01018. Specifications for 3m scotchshield safety and security window film, ultra s800. Glass strength evaluation prior to astm e 0 prior to the introduction of the astm e 0 standard there were other methods used in the united states to evaluate glass strength for buildings. Blast mitigation information graham architectural products.
Ufc 401001, minimum antiterrorism standards for buildings 4. Dod ufc 401001 atfp isc security design criteria for blast protection for windows astm f 1642 far 52. Bomb blast protection not all laminated glass is the same, and the same glass configuration may not meet every facilitys needs. For annual book of astm standards volume information, refer to the standards document summary page on the astm website. Astm c1036, c1048, c76 and c1172 with insulating glass units meeting astm e 773 and 774 as applicable. The primary glass manufacturers counsel pgmc and glass association of north america gana endorses the window glass design 2002 program as being the best tool available to aid in designing window glass to resist wind and longterm loadings. This standard is the sole test protocol by which blast resistant windows and related hazard mitigation technology and products shall be. With engineering, analysis and data compiled from our own open air arena blast tests conducted per astm f 164204 at a peak overpressure of 6 psi and a positive phase impulse of 42 psimsec. Astm e2112, standard practice for installation of exterior windows,doors and skylights i just spent about 10 minutes searching for this document with no luck. Enables the user to size rectangular laminated glass and insulating glass constructed with at least one laminated glass lite to resist user. Blast mitigating glazing can substantially reduce injury from flying glass resulting from.
Gsa rating of 3b astm f1642 low hazard with blast minimum load of 10 psi. This document provides a broad overview, but may not include all. Common testing methods outlined in these standards include shock tube, where impulse. Window glass design performs all the calculations required to design glass according to astm e 0. Kawneertraco offers engineered solutions for entrances, framing, curtain walls and windows.
Pdf this paper deals with the deflection of double glazed unit made of glass. Astm e 84 standard method of test for surface burning characteristics of building materials astm d1004 standard method of test for resistance of transparent plastics to tearing graves tear test astm e 1886 standard test method for performance of exterior windows, curtain walls, doors, and impact protective systems impacted by. In the 1960s and into the 1980s most architects and engineers used one simple chart that described the assumed strength of each glass thickness. A number in parentheses indicates the year of last reapproval. Astm e012a material engineering general discussion. Astm f224819, standard practice for specifying an equivalent 3second duration design loading for blast resistant glazing fabricated with laminated glass, astm international, west conshohocken, pa, 2019. This practice describes procedures to determine the load resistance lr of specified glass types, including combinations of glass types used in a sealed insulating glass ig unit, exposed to a uniform lateral load of short or long duration, for a specified probability of breakage. With years of engineering experience and data collected from open air arena blast testing, kawneertraco can offer engineered solutions to protect against a range of blast events. Hygard ex0 is one component in a blast resistant window and must be modeled and tested in structural framing which is designed and approved for specified. Standard practice for determining load resistance of glass in buildings. Standard practice for determining load resistance of glass. Blast resistant fixed window series bw8100 the series bw8100 blast resistant fixed window offers that rare combination of durability and toughness to meet blast mitigation requirements. An important new standard, astm e 0 astm e 0, the design load, the equivalent. Armortex has been manufacturing bullet, blast and forced entry resistant products for more than thirty years.
Standard practice for determining load resistance of glass in. Astm standard e 0 uses glasstype factors that relate the strength of other monolithic window glass types heat strengthened and fully tempered and. Astm e 1233 standard test method for structural performance of exterior windows, doors, skylights, and curtain walls by cyclic air pressure differential astm e 0 standard practice for determining load resistance of glass in buildings astm e 32 standard classification for determination of outdoorindoor transmission class. Designing window glass using astm e 0 variations of magnitudes of these lateral. Aama window standards specifications and ratings, testing. Analysis and design of structural glass systems jose sanches instituto superior tecnico, technical university of lisbon january 20 jose. While total protection from bomb blasts and explosions is not possible, there are steps we can take to mitigate the extent or even likelihood of damage.
Astm e0 standard practice for determining load resistance of glass in buildings annealed. Security glazing specification 1 general 2 materials minimum. This software also performs window glass design using astm e 0 020304, astm e 0 9800 and astm e 0 94. Window replacement low to moderate blast window, thicker glass or. On the deflection of window glass subjected to lateral forces. Standard test methods for tension testing of metallic materials1. Pdf on the deflection of window glass subjected to. Considerations for blastresistant glazing design texas tech. Astm e0 wind load calculator this calculator makes it easy for you to perform preliminary assessments of the wind load resistance of single glazed, annealed not heat treated window glass, with various edge support conditions, according to the astm e0 standard. Have received specific training in the proper installation of the specified system and will be present to supervise whenever material is being installed. Gsa rating of 2 minimal hazard astm f1642 no hazard with blast pressure of 7 psi and 42 psimsec.
Astm e2112, standard practice for installation of exterior. E016 standard practice for determining load resistance of glass in buildings. Our product line includes armortexr brand fiberglass composite panels, glass and containment glazing, fixed windows and transaction windows, passthru transaction equipment drawers, hoppers, dip trays, speakers, gun ports, gun lockers and man traps. Astm e 0, standard practice for determining load resistance of glass in buildings 5. Security glazing specification 1 general 2 materials.
Astm e 1996 standard specification for performance of exterior windows, curtain walls, doors and impact protective systems impacted by windborne debris in hurricanes astm e 2010 standard test method for positive pressure fire tests of window assemblies astm e 2074 standard test method for fire tests of door assemblies, including. Applicable blast test standard astm f292712 astm f164212. Astm e 009a astm 2009 to select an appropriate glass type and a. Gsa rating of 3b astm f1642 low hazard with blast minimum load of 10 psi and 42 psimsec, on 1 inch 25 mm double pane glass without film attachment. It, along ing motion, and blast pressures have been docu. Pdf design guidance for blastresistant glazing researchgate.
Astm d 1003 % 67 haze astm d 1003 % 0 standard practice for determining the load resistance of glass in buildings to select the thickness and type of blast. The glass association of north america gana endorses the window glass design 5 program as being the best tool available to aid in designing window glass to. Find glass load capacity astm e 0 connection design all parts, including glazing stop allowable stress levels. E 0 03 an american national standard standard practice for determining load resistance of glass in buildings1 this standard is issued under the. A comparison of existing standards for testing blast resistant glazing and windows december 2014 editor. Window glass design 5 wgd5 performs all required calculations to design window glass according to astm e 0 09. Performance of windows, doors, skylights, and curtain walls. Astm e012a astm e012a warhamer structural op 23 sep 15 15. During impact testing, the glass panes in the system can fracture but the interlayer must remain intact to prevent. The defender series of blast mitigation products are designed to provide protection for.